{"id":884,"date":"2024-04-29T14:44:59","date_gmt":"2024-04-29T14:44:59","guid":{"rendered":"https:\/\/iramed.webs.upv.es\/?page_id=884"},"modified":"2024-05-10T10:51:39","modified_gmt":"2024-05-10T10:51:39","slug":"wp-02","status":"publish","type":"page","link":"https:\/\/iramed.webs.upv.es\/?page_id=884","title":{"rendered":"Work Package 02"},"content":{"rendered":"\n<div class=\"wp-block-group alignwide eplus-wrapper is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-columns eplus-wrapper is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex eplus-styles-uid-b0ef39\">\n<div class=\"wp-block-column eplus-wrapper is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\" has-medium-font-size eplus-wrapper\"><strong>O2. DOSE REDUCTION IN NUCLEAR MEDICINE(PET-CT)<\/strong><\/p>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-columns eplus-wrapper is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex eplus-styles-uid-fc4b66\">\n<div class=\"wp-block-column is-vertically-aligned-center eplus-wrapper is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\" eplus-wrapper\">Positron Emission Tomography (PET) is one of the most used techniques for obtaining functional images in applications such as oncology, neurology and cardiology. Dosimetry in patients undergoing PET is of vital importance to ensure the safety of the procedure. All radiodiagnostic equipment (x-rays, mammography, CT, PET-CT and SEPT-CT) must have software capable of evaluating the dose received by the patient at the end of each diagnostic treatment. Therefore, it is essential to develop methods to estimate the doses received in internal organs due to the ionizing radiation imparted and to address how to reduce these doses.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column eplus-wrapper is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\" wp-block-image aligncenter size-full is-resized eplus-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"223\" height=\"272\" src=\"https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/Proyecto_mtlg_O2.png\" alt=\"\" class=\"wp-image-1070\" style=\"width:274px;height:auto\"><\/figure>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-columns eplus-wrapper is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex eplus-styles-uid-feb458\">\n<div class=\"wp-block-column eplus-wrapper is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\" eplus-wrapper\">The tasks involved are:<\/p>\n\n\n\n<p class=\" eplus-wrapper\">&#8211; Task 2.1. Development of internal dosimetry models from the GEANT-GATE and GEANT-GAMOS toolkits. The models include the PET scanner and mathematical and anthropomorphic phantoms, the latter obtained from the segmentation and voxelization of DICOM CT images.<\/p>\n\n\n\n<p class=\" eplus-wrapper\">&#8211; Task 2.2. Reconstruction of PET images from Monte Carlo simulations. Application to mathematical and anthropomorphic phantoms. Study of different reconstruction techniques. Fusion of dose maps and reconstructed images. Application to different clinical trials.<\/p>\n\n\n\n<p class=\" eplus-wrapper\">&#8211; Task 2.3. Comparison of the images generated by Monte Carlo with images from real clinical trials. Qualitative and quantitative characterization of errors between real and simulated images. Study of the possible assignment of the dose map obtained by simulation to real images.<\/p>\n\n\n\n<p class=\" eplus-wrapper\">&#8211; Task 2.4. Software validation with calibrated MOSFET detectors. Experimentally determine the dose delivered to dummies with the MOSFETs, and then, the comparison between the values calculated by Monte Carlo and the experimental dose<\/p>\n<\/div>\n<\/div>\n\n\n<figure class=\" wp-block-image aligncenter size-large is-resized eplus-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"176\" src=\"https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/MTLG_02_ENG-1024x176.png\" alt=\"\" class=\"wp-image-1204\" style=\"width:1450px;height:auto\" srcset=\"https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/MTLG_02_ENG-1024x176.png 1024w, https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/MTLG_02_ENG-300x51.png 300w, https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/MTLG_02_ENG-768x132.png 768w, https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/MTLG_02_ENG-1536x263.png 1536w, https:\/\/iramed.webs.upv.es\/wp-content\/uploads\/2024\/05\/MTLG_02_ENG-2048x351.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>O2. DOSE REDUCTION IN NUCLEAR MEDICINE(PET-CT) Positron Emission Tomography (PET) is one of the most used techniques for obtaining functional [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"editor_plus_copied_stylings":"{}","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-884","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=\/wp\/v2\/pages\/884","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=884"}],"version-history":[{"count":12,"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=\/wp\/v2\/pages\/884\/revisions"}],"predecessor-version":[{"id":1525,"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=\/wp\/v2\/pages\/884\/revisions\/1525"}],"wp:attachment":[{"href":"https:\/\/iramed.webs.upv.es\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=884"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}